Diesel & Electric Ventilator
©Trench Plate® Rental Co All Rights Reserved..
► Diesel Ventilator
18” Inlet – Outlet
All Required OSHA Guards and Screens
Flashing Strobe Light when Operating
Fuel Requirements, 5 Gal. For 8 hrs.
12,000 CFM Ventilator
Quiet and Economical
Diesel Operated
Aluminum Impeller (reduced explosion risk)
► Electric Ventilator
Designed and manufactured to improve efficiency and working conditions in various underground, confined, and outdoor areas.
|
490 CFM
|
553 CFM
|
|
12 Volt DC, 15 Amps
|
120 Volt AC, 3 Amps
|
|
40 lbs. 25’ Hose
|
40 lbs. 25’ Hose
|


Forced Air Ventilation is the primary engineering control used to maintain safe atmospheric conditions in confined spaces. The confined space should be ventilated using the following guidelines:
1. Locate the blower a safe distance from the confined space;
2. Ensure that the air supply is not contaminated;
3. If ventilation equipment blocks or restricts access to the confined space, precautions must be taken to provide entrants with respirable air for the time necessary to exit the space (Note: Using a saddle vent is a good way to avoid this problem altogether.) ;
4. If a flammable atmosphere exists or may develop, the ventilating equipment must be properly bonded and grounded to prevent a static discharge;
5. Continuous ventilation should be maintained for the duration of the entry; and,
6. When ventilating to eliminate a hazardous atmosphere, the blower should be run for a sufficient length of time. The atmosphere should then be re-tested to determine if conditions are safe for entry.
Confined Space Ventilation Purge Time Chart - Air Exchange 7.5 Times
Effective Blower Capacity - CFM

Ventilation Equipment / Ventilators